| Isolator RF Drop-in RFTYT 34MHz-31.0GHz | |||||||||
| Modél | Rentang Frékuénsi (MHz) | Lebar pita (Maks) | Leungitna Sisipan (dB) | Isolasi (dB) | VSWR (Maks) | Kakuatan Maju (W) | TibalikKakuatan (W) | Diménsi P x L x T (mm) | Lembar data |
| WG6466H | 30-40 | 5% | 2.00 | 18.0 | 1.30 | 100 | 20/100 | 64.0*66.0*22.0 | |
| WG6060E | 40-400 | 50% | 0.80 | 18.0 | 1.30 | 100 | 20/100 | 60.0*60.0*25.5 | |
| WG6466E | 100-200 | 20% | 0.65 | 18.0 | 1.30 | 300 | 20/100 | 64.0*66.0*24.0 | |
| WG5050X | 160-330 | 20% | 0.40 | 20.0 | 1.25 | 300 | 20/100 | 50.8*50.8*14.8 | |
| WG4545X | 250-1400 | 40% | 0.30 | 23.0 | 1.20 | 300 | 20/100 | 45.0*45.0*13.0 | |
| WG4149A | 300-1000 | 50% | 0.40 | 16.0 | 1.40 | 100 | 20 | 41.0*49.0*20.0 | |
| WG3538X | 300-1850 | 30% | 0.30 | 23.0 | 1.20 | 300 | 20 | 35.0*38.0*11.0 | |
| WG3546X | 300-1850 | 30% | 0.30 | 23.0 | 1.20 | 300 | 20dB 30dB 100W | 35.0*46.0*11.0 | PDF 20dB PDF 30dB 100W PDF |
| WG2525X | 350-4300 | 25% | 0.30 | 23.0 | 1.20 | 200 | 20 | 25.4*25.4*10.0 | |
| WG2532X | 350-4300 | 25% | 0.30 | 23.0 | 1.20 | 200 | 20dB 30dB 100W | 25.4*31.7*10.0 | PDF 20dB PDF 30dB 100W PDF |
| WG2020X | 700-4000 | 25% | 0.30 | 23.0 | 1.20 | 100 | 20 | 20.0*20.0*8.6 | |
| WG2027X | 700-4000 | 25% | 0.30 | 23.0 | 1.20 | 100 | 20dB 30dB 100W | 20.0*27.5*8.6 | PDF 20dB PDF 30dB 100W PDF |
| WG1919X | 800-5000 | 25% | 0.30 | 23.0 | 1.20 | 100 | 20 | 19.0*19.0*8.6 | |
| WG1925X | 800-5000 | 25% | 0.30 | 23.0 | 1.20 | 100 | 20dB 30dB 100W | 19.0*25.4*8.6 | PDF 20dB PDF 30dB 100W PDF |
| WG1313T | 800-7000 | 25% | 0.30 | 23.0 | 1.20 | 60 | 20 | 12.7*12.7*7.2 | PDF (ngaliwatan liang) |
| WG1313M | 800-7000 | 25% | 0.30 | 23.0 | 1.20 | 60 | 20 | 12.7*12.7*7.2 | PDF (liang sekrup) |
| WG6466K | 950-2000 | Pinuh | 0.70 | 17.0 | 1.40 | 100 | 20/100 | 64.0*66.0*26.0 | |
| WG5050A | 1.35-3.0 GHz | Pinuh | 0.70 | 18.0 | 1.30 | 150 | 20/100 | 50.8*49.5*19.0 | |
| WG4040A | 1.6-3.2 GHz | Pinuh | 0.70 | 17.0 | 1.35 | 150 | 20/100 | 40.0*40.0*20.0 | |
| WG3234A WG3234B | 2.0-4.2 GHz | Pinuh | 0.50 | 18.0 | 1.30 | 150 | 20 | 32.0*34.0*21.0 | PDF (liang sekrup) (ngaliwatan liang) |
| WG3030B | 2.0-6.0 GHz | Pinuh | 0.85 | 12.0 | 1.50 | 50 | 20 | 30.5*30.5*15.0 | |
| WG2528C | 3.0-6.0 GHz | Pinuh | 0.50 | 20.0 | 1.25 | 100 | 20/100 | 25.4*28.0*14.0 | |
| WG2123B | 4.0-8.0 GHz | Pinuh | 0.60 | 18.0 | 1.30 | 50 | 10 | 21.0*22.5*15.0 | |
| WG1623D | 5.0-7.3 GHz | 20% | 0.30 | 20.0 | 1.25 | 100 | 5 | 16.0*23.0*9.7 | |
| WG1220D | 5.5-7.0 GHz | 20% | 0.40 | 20.0 | 1.20 | 50 | 5 | 12.0*20.0*9.5 | |
| WG0915D | 6.0-18.0 GHz | 40% | 0.40 | 20.0 | 1.25 | 30 | 5 | 8.9*15.0*7.8 | |
| WG1622B | 6.0-18.0 GHz | Pinuh | 1.50 | 9.50 | 2.00 | 30 | 5 | 16.0*21.5*14.0 | |
| WG1319C | 8.0-18.0 GHz | 40% | 0.70 | 16.0 | 1.45 | 10 | 10 | 12.0*15.0*8.6 | |
| WG1017C | 18.0-31.0 GHz | 38% | 0.80 | 20.0 | 1.35 | 10 | 2 | 10.2*17.6*11.0 | |
Isolator Drop-in nyaéta alat éléktronik anu dianggo pikeun ngahontal isolasi sinyal RF dina hiji sirkuit. Isolator Drop-in mibanda bandwidth frékuénsi anu khusus. Dina passband, sinyal tiasa dikirimkeun kalayan lancar ti Rx Port 1 ka Anteneu Port 2 dina arah anu ditangtukeun. Nanging, kusabab isolasi na, sinyal ti Anteneu Port 2 teu tiasa dikirimkeun ka Tx Port 1. Ku alatan éta, éta ngagaduhan fungsi transmisi hiji arah, ogé katelah transformator hiji arah.
Isolator Drop-in diwangun ku rongga, magnet anu muter, konduktor jero, sareng medan magnet bias. Dua liang las konduktor jero nonjol ti luar rongga, janten merenah pikeun konsumén pikeun ngelas nganggo papan sirkuit. Sacara umum, isolator Drop-in gaduh liang pamasangan kalayan liang tembus atanapi liang ulir, janten merenah pikeun konsumén pikeun masang.
Isolator drop-in utamina dianggo pikeun ngajagi alat-alat front-end, sareng aplikasi anu paling umum nyaéta pikeun ngajagi tabung amplifier daya dina amplifier daya RF (sinyal anu dikuatkeun tina tabung amplifier daya dikirimkeun ka anteneu ngalangkungan isolator Drop-in, sareng upami anteneu henteu cocog, sinyal henteu tiasa dipantulkeun ka tungtung hareup isolator, mastikeun yén tabung amplifier daya henteu kaduruk).
Port beban tina isolator Drop-in ogé gaduh attenuator chip 20dB atanapi 30dB anu disambungkeun. Fungsi attenuator chip ieu nyaéta pikeun ngadeteksi ketidakcocokan port anteneu. Upami ketidakcocokan port anteneu kajantenan, sinyal dikirimkeun ka attenuator chip, sareng saatos atenuasi 20dB atanapi 30dB, sinyal parantos buruk kana kaayaan anu luar biasa lemah. Sareng insinyur tiasa nganggo sinyal lemah ieu pikeun ngontrol sirkuit front-end, sapertos mareuman sareng operasi sanésna.